Solid-state Relay G3M Zero Cross Models Added to Compact, Low-cost G3M Series Thin design for high-density PCB applications. DC input-AC output for up to a 3-A load. Approved by UL and CSA. RCE Ordering Information Isolation Input terminal pitch Zero cross function Indicator Phototriac 7.62 mm Yes No Rated output load (Applicable output load) 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) Rated input voltage 5 VDC Model G3M-202P-US 12 VDC 24 VDC 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) 5 VDC G3M-203P 12 VDC 24 VDC No 2 A at 100 to 120 VAC (2 A at 75 to 132 VAC) 5 VDC G3M-102PL-US 12 VDC 24 VDC 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 5 VDC G3M-202PL-US 12 VDC 24 VDC 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) 5 VDC G3M-203PL 12 VDC 24 VDC 5 A at 100 to 240 VAC (5 A at 75 to 264 VAC) 5 VDC 12 VDC 24 VDC Note: 1. TUV marking is available with "-UTU" in place of "-US" on the part number. 2. UL, CSA and VDE approval of G3M-205PL is pending. 218 G3M-205PL (New) G3M G3M Isolation Input terminal pitch Zero cross function Indicator Phototriac 5.08 mm Yes No Rated output load (Applicable output load) 2 A at 100 to 240 VAC (2 A at 75 to 132 VAC) Rated input voltage 5 VDC Model G3M-202P-US-4 12 VDC 24 VDC 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) 5 VDC G3M-203P-4 12 VDC 24 VDC No 2 A at 100 to 120 VAC (3 A at 75 to 264 VAC) 5 VDC G3M-102PL-US-4 12 VDC 24 VDC 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 5 VDC G3M-202PL-US-4 12 VDC 24 VDC 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) 5 VDC 5 A at 100 to 240 VAC (5 A at 75 to 264 VAC) 5 VDC G3M-203PL-4 24 VDC 12 VDC G3M-205PL-4 (New) 24 VDC Note: TUV marking is available with "-UTU" in place of "-US" on the part number. Specifications Ratings Input Rated voltage Operating voltage Impedance Voltage levels Must operate voltage 5 VDC 4 to 6 VDC 300 20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 800 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 1.6 k 20% 19.2 VDC max. Note: Must release voltage 1 VDC min. Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Output Model Rated voltage Applicable load Load voltage G3M-102PL-US (-4) 100 to 120 VAC 75 to 132 VAC G3M-202P(L)-US (-4) 100 to 240 VAC 75 to 264 VAC Load current Inrush current 0.1 to 2 A 30 A (60 Hz, 1 cycle) G3M-203P(L) (-4) 0.1 to 3 A 45 A (60 Hz, 1 cycle) G3M-205P(L) (-4) 0.1 to 5 A 219 G3M G3M Characteristics Item G3M-102PL-US (-4) G3M-202P(L)-US (-4) G3M-203P (L) (-4) G3M-205P (L) (-4) Operate time 1 ms max. (1/2 of load power source cycle + 1 ms max. for G3M-202P, G3M-203P, G3M-205P) Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 2 mA max. (at 100 VAC) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing or condensation) Storage: -30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Weight Approx. 15 g 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 1.5 mA (at 200 VAC) 2,500 VAC, 50/60 Hz for 1 min Approx. 25 g Approved Standards Approved by UL (Report No. E64562) G3M-202P(L)-US(-4) G3M-203P(L)(-4) Approved by CSA (Report No. LR35535) G3M-202P(L)-US(-4) G3M-203P(L)(-4) Approved by TUV G3M-202P(L)-UTU(-4) G3M-203P(L)-UTU(-4) Engineering Data Load Current vs. Ambient Temperature Inrush Current Immunity Non-repetitive Reduce the current to 1/2 or less if the G3M is in repetitive operation. G3M-203P(L)(-4) G3M-102PL-US(-4) G3M-202P(L)-US(-4) Inrush peak current (A) Load current (A) G3M-205P(L)(-4) G3M-203P(L)(-4) G3M-205P(L)(-4) G3M-102PL-US(-4) G3M-202P(L)-US(-4) Ambient temperature (C) 220 Energizing time (ms) G3M G3M Dimensions Note: All units are in millimeters unless otherwise indicated. G3M-102P-US(-4), G3M-202P(L)-US(-4) G3M-203P(L)(-4) PCB Dimensions (Bottom View) 9 max. 40 max. 2.54 Four, 1.2 dia. holes 20 max. 2.54 4 3 2 4 1 4 42 7.620.2 (5.08)* 12.70.2 10.160.2 4 3 2 1 0.4 0.7 "-4" type 31 Terminal Arrangement (Bottom View) G3M-205P(L)(-4) 7.6 max. 40 max. Input voltage Load power supply Load 25 max. 4 Input 4 3 2 0.7 42 7.62 (5.08)* 12.7 Load 1 10.16 0.4 1.65 *Input terminal pitch of 5.08 mm is also available. Precautions Protective Element No overvoltage absorption element is built in. Therefore, if the G3M is connected to an inductive load, be sure to connect the overvoltage absorption element. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K073-E1-1D 221